全网唯一标准王
43 湖 南 省 地 方 标 准ICS 07.060.47 CCS A 47 水质自动监测系统防雷技术规范 Technical specification for lightning protection of water quality automatic monitoring system 发 布 湖南省市场监督管理局2025-07发布-18 2025-10实施-18DB43/T 3295—2025DB43/T 3295—2025 I 目 次 前言 ································································································ ························ Ⅲ 1 范围 ································································································ ····················· 1 2 规范性引用文件 ································································································ ······ 1 3 术语和定义 ································································································ ············ 1 4 一般要求 ································ ································ ··············································· 2 5 雷电防护装置设计 ································································································ ··· 2 6 雷电防护装置施工 ································································································ ··· 5 7 维护和管理 ································································································ ············ 7 附录A(资料性) 防雷区的划分 ···················································································· 8 DB43/T 3295—2025 II DB43/T 3295—2025 III 前 言 本文件按照GB/T 1.1 —2020《标准化工作导则 第1部分:标准化文件的结构和起草规则》的规定 起草。 请注意本文件的某些内容可能涉及专利,本文件发布机构不承担识别专利的责任。 本文件由湖南省气象局提出。 本文件由湖南省气象标准化技术委员会归口。 本文件起草单位:湖南省气象灾害防御技术中心、湖南省生态环境监测中心、株洲市气象局、永州 市气象局、长沙市气象局、娄底市气象局、邵阳市气象局。 本文件主要起草人:邓战满、甘杰、李濠、杨建友、曾进、肖金、刘帅、李建钊、贺秋艳、谭杰、 陈阳、刘思诗、秦婷、李剑俊、 江勇、李玮、肖林利、罗龙友。 DB43/T 3295—2025 IV DB43/T 3295—2025 1 水质自动监测系统防雷技术规范 1 范围 本文件规定了水质自动监测系统雷电防护的一般要求、雷电防护装置设计、施工、维护和管理防雷 技术要求。 本文件适用于新(改、扩)建固定式、简易式、小型式等水质自动监测系统的雷电防护装置的设计、 施工、验收及日常维护。 2 规范性引用文件 下列文件中的内容通过文中的规范性引用而构成本文件必不可少的条款。 其中, 注日期的引用文件, 仅该日期对应的版本适用于本文件;不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。 GB/T 21431 建筑物雷电防护装置监测技术规范 GB 50057— 2010 建筑物防雷设计规范 GB 50343— 2012 建筑物电子信息系统防雷技术规范 GB 50601— 2010 建筑物防雷工程施工与质量验收规范 3 术语和定义 下列术语和定义适用于本文件。 3.1 水质自动监测系统 automatic water quality monitoring system 由水站和数据平台组成的自动监测系统 [来源:HJ 915—2017 地表水自动监测技术规范, 3.4] 3.2 防雷区 lightning protection zone (LPZ) 划分雷击电磁环境的区,一个防雷区的区界面不一定要有实物界面,如不一定要有墙壁、地板或天 花板作为区界面。 [来源:GB 50057—2010 ,2.0.24] 3.3 雷电防护装置 lightning protection system ;LPS 防雷装置 用来减小雷击建筑物造成物理损害的整个系统 。 注:LPS由外部和内部雷电防护装置两部分构成 。 [来源:GB/T 21431 —2023,3.1] 3.4 接闪器 air-termination system DB43/T 3295—2025 2 由拦截闪击的接闪杆、接闪带、接闪线、接闪网以及金属屋面、金属构件等组成。 [来源:GB 50057—2010 ,2.0.8] 3.5 引下线 down -conductor system 用于将雷电流从接闪器传导至接地装置的导体 。 注:可分为专设引下线和利用建筑物的钢结构或混凝土结构内钢筋作自然引下线两种类型。 [来源:GB 50057—2010,2.0.9, 有修改] 3.6 接地装置 earth -termination system 接地体和接地线的总合 , 用于传导雷电流并将其流散入大地 。 [来源:GB 50057—2010,2.0.10] 3.7 电涌保护器 surge protective device (SPD) 用于限制瞬态过电压和分泄电涌电流的器件。它至少含有一个非线性元件。 [来源:GB 50057—2010 ,2.0.29] 3.8 电气系统 electrical system 由低压供电组合部件构成的系统。也称低压配电系统或低压配电线路。 [来源:GB 50057—2010 ,2.0.26] 3.9 电子系统 electronic system 含有敏感电子部件 , 如通信设备 、计算机 、控制和仪表系统 、无线电系统 、电力电子装置的系 统 。 [来源:GB/T 21714.1—2015 ,3.29] 4 一般要求 4.1 水质自动监测系统宜在建设前进行雷电灾害风险评估。并结合其重要性、当地地理环境、雷电活 动规律进行防雷分级防护,其等级划分符合GB 50057 、GB 50343要求。 4.2 雷电防护范围包括主体建(构)筑物、仪器设备,以及为站点提供安防、电力和通讯等功能使用 的设备设施。 4.3 雷电防护措施应依据站房设计、仪器设备等不同站点形式、站房结构进行。 4.4 水质自动监测系统年预计雷击次数按照GB50057 —2010附录A计算,校正系数应按照临近水域的系 数进行选择。 4.5 水质自动监测系统的雷电防护装置设计、施工 宜与站房的建设或改造同步进行。不影响站内监测 仪器的正常运行和监测数据的准确性。 5 雷电防护装置设计 5.1 接闪器 5.1.1 水质自动监测系统宜采用接闪杆、接闪带或接闪网作为接闪器,其保护范围应按滚球法确定,

.pdf文档 DB43-T 3295-2025 水质自动监测系统防雷技术规范 湖南省

文档预览
中文文档 14 页 50 下载 1000 浏览 0 评论 309 收藏 3.0分
温馨提示:本文档共14页,可预览 3 页,如浏览全部内容或当前文档出现乱码,可开通会员下载原始文档
DB43-T 3295-2025 水质自动监测系统防雷技术规范 湖南省 第 1 页 DB43-T 3295-2025 水质自动监测系统防雷技术规范 湖南省 第 2 页 DB43-T 3295-2025 水质自动监测系统防雷技术规范 湖南省 第 3 页
下载文档到电脑,方便使用
本文档由 人生无常 于 2026-03-20 21:15:33上传分享
友情链接
站内资源均来自网友分享或网络收集整理,若无意中侵犯到您的权利,敬请联系我们微信(点击查看客服),我们将及时删除相关资源。