全网唯一标准王
43 湖 南 省 地 方 标 准ICS 07.060.47 CCS A 47 环境空气自动监测站防雷技术规范 Technical specification for lightning protection of ambient air automatic monitoring station 发 布 湖南省市场监督管理局2025-07发布-18 2025-10实施-18DB43/T 3294—2025DB43/T 3294—2025 I 目 次 前言 ································································································ ························ Ⅲ 1 范围 ································································································ ····················· 1 2 规范性引用文件 ································································································ ······ 1 3 术语和定义 ································································································ ············ 1 4 一般要求 ································ ································ ··············································· 2 5 雷电防护装置设计 ································································································ ··· 2 6 雷电防护装置施工 ································································································ ··· 5 7 维护和管理 ································································································ ············ 6 附录A(资料性) 防雷区的划分 ···················································································· 7 参考文献 ································ ···················································································· 8 DB43/T 3294—2025 II DB43/T 3294—2025 III 前 言 本文件按照GB/T 1.1—2020 《标准化工作导则 第1部分:标准化文件的结构和起草规则》的规定 起草。 请注意本文件的某些内容可能涉及专利,本文件发布机构不承担识别专利的责任。 本文件由湖南省气象局提出。 本文件由湖南省气象标准化技术委员会归口。 本文件起草单位:湖南省气象灾害防御技术中心、湖南省生态环境监测中心、湘西土家族苗族自治 州气象局、永州市气象局、郴州市气象局。 本文件主要起草人:杨建友、甘杰、邓战满、李濠、周国军、郭卉、曾进、李建钊、胡欣、陈阳、 胡美琼、金红红、秦婷、王里豪、张清超、顾雪、范智渊。 DB43/T 3294—2025 IV DB43/T 3294—2025 1 环境空气自动监测站防雷技术规范 1 范围 本文件规定了环境空气自动监测站雷电防 护的一般要求、雷电防护装置设计、施工、维护和管理。 本文件适用于新建、改建和扩建环境空气自动监测站的雷电防护。 2 规范性引用文件 下列文件中的内容通过文中的规范性引用而构成本文件必不可少的条款。 其中, 注日期的引用文件, 仅该日期对应的版本适用于本文件;不注日期的引用文件,其最新版本(包括所有的修改单)适用于本 文件。 GB/T 21431 建筑物雷电防护装置监测技术规范 GB 50057— 2010 建筑物防雷设计规范 GB 50343— 2012 建筑物电子信息系统防雷技术规范 GB 50601— 2010 建筑物防雷工程施工与质量验收规范 3 术语和定义 下列术语和定义适用于本文件。 3.1 站房 station houses 由用于开展环境空气监测活动的建筑物即站房主体、电力设备、温湿度控制设备、防雷设备、安防 设备、网络设备和自动质控单元组成。 3.2 环境空气自动监测站 automatic environmental air monitoring station 采用自动监测仪器对空气环境要素进行连续或定时采样、处理、分析及数据传输的监测站。 3.3 雷电防护装置 lightning protection system ;LPS 防雷装置 用来减小雷击建筑物造成人身伤害和物理损害的整个系统 。 注1:LPS由外部和内部雷电防护装置两部分构成。 [来源:GB/T 21431 —2023,3.1] 3.4 防雷区 lightning protection zone (LPZ) 划分雷击电磁环境的区,一个防雷区的区界面不一定要有实物界面,如不一定要有墙壁、地板或天 花板作为区界面。 [来源:GB 50057—2010 ,2.0.24] DB43/T 3294—2025 2 3.5 接闪器 air-termination system 由拦截闪击的接闪杆、接闪带、接闪线、接闪网以及金属屋面、金属构件等组成。 [来源:GB 50057—2010 ,2.0.8] 3.6 引下线 down -conductor system 用于将雷电流从接闪器传导至接地装置的导体 。 [来源:GB 50057—2010,2.0.9, 有修改] 3.7 接地装置 earth -termination system 接地体和接地线的总合, 用于传导雷电流并将其流散入大地 。 [来源:GB 50057—2010,2.0.10] 3.8 防雷等电位连接 lightning equipotential bonding (LEB) 将分开的诸金属物体直接用连接导体或经电涌保护器连接到防雷装置上以减小雷电流引发的电位 差。 [来源: GB 50057— 2010,2.0.19] 3.9 电涌保护器 surge protective device (SPD) 用于限制瞬态过电压和分泄电涌电流的器件。它至少含有一个非线性元件。 [来源:GB 50057—2010 ,2.0.29] 4 一般要求 4.1 环境空气自动监测站宜在建设前进行雷电灾害风险评估,并结合其重要性和雷电活动特征进行防 雷分级防护,其等级划分符合GB 50057、 GB 50343 要求。 4.2 雷电防护范围包括主体建(构)筑物、 监测设备、安防设备以及为站点提供电力和通讯等功能使 用的设备设施。 4.3 环境空气自动监测站年预计雷击次数按照 GB 50057—2010 附录A计算,校正系数应按照临近水域的 系数进行选择。 4.4 环境空气自动监测站的雷电防护装置设计、施工宜与站房的建设或改造同步进行,不影响站内监 测仪器的正常运行和监测数据的传输。 5 雷电防护装置设计 5.1 接闪器 5.1.1 接闪器的保护范围应按滚球法计算,滚球半径取值宜为 45 m。 5.1.2 建设于建筑物屋面的环境空气自动监测站,宜在建筑物屋面安装接闪带、接闪杆相结合的接闪 器。接闪器、站房屋面的金属护栏应与建筑物的雷电防护装置做等电位连接。 5.1.3 单独建设的环境空气自动监测站采用接闪杆,并与站房的安全距离不应小于 3 m。 5.1.4 伸出屋面的采样系统、监测设备以及站房屋面的金属护栏应位于接闪器的保护范围内,

.pdf文档 DB43-T 3294-2025 环境空气自动监测站防雷技术规范 湖南省

文档预览
中文文档 14 页 50 下载 1000 浏览 0 评论 309 收藏 3.0分
温馨提示:本文档共14页,可预览 3 页,如浏览全部内容或当前文档出现乱码,可开通会员下载原始文档
DB43-T 3294-2025 环境空气自动监测站防雷技术规范 湖南省 第 1 页 DB43-T 3294-2025 环境空气自动监测站防雷技术规范 湖南省 第 2 页 DB43-T 3294-2025 环境空气自动监测站防雷技术规范 湖南省 第 3 页
下载文档到电脑,方便使用
本文档由 人生无常 于 2026-03-20 21:15:29上传分享
友情链接
站内资源均来自网友分享或网络收集整理,若无意中侵犯到您的权利,敬请联系我们微信(点击查看客服),我们将及时删除相关资源。