全网唯一标准王
TR 62493-1 @ IEC:2013(E) - 11 - A change inthe measurementprocedureinIEC64293isneededto avoid this misinterpretation.The activities to resolve this problem in IEC 62493 have been started. 4.4 Evaluation of the influenceof certain characteristicsof theluminaires The following evaluations show the influence on the EMF results measured according IEC62493 resultingfrom specificcharacteristics of the luminaires. Examples of the to identify construction details of luminaires which are critical for the EMF measurements. All tables are sorted for the average of the measured results (highest average measurement value is on top). Here average means that this is the average of the results of all measured luminaires with the same specification. (Scientific), Inc.. To avoid any deviation caused by the single critical luminaire that showed a huge difference between AC and DC mode, only the DC results of this luminaire have been used in the tables below. In all tables,the columns are structured in the same way as shown in Table1. subscriptions.techstreet.com, d Table1-Structureoftables Column Description Parameter which is varied. This can be the type of the luminaire or some characteristics (e.g. First column material, lamp technology,lamp cover,type of lamp) Number of This column gives the absolute number of samples which have the characteristic given in the samples first column This is the linear average of the measured results (factor F according IEC 62493) during the Average value investigations All values in the tables are sorted in descending order using the values of this column. Max value This gives the maximum value of all measured results (factor F according IEC 62493) in the group of samples 4.5 TypeofluminairesaccordingTableA.1ofIEC62493:2009 Table A.1 of IEC 62493:2009 determines the distance to the test head which is required for measurement. The rowwiththenumber (23)in Table 2is used mostly for luminaires with LEDlampswhich are intended for ceiling and recessed mounting. The standard in its present edition often refers mostly to luminaires with fluorescent lamps in Table A.1 of IEC 62493:2009.Therefore luminaires with LED are mostly in this row. Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permited. Uncontrolled when print - 12 - TR62493-1@IEC:2013(E) Table 2-Measurement results of luminaire types in accordance with Table A.1of IEC 62493:2009 Measurement results Measurement Number of (Factor F) Typeof lightingequipmentaccordingto distance Table A.1of IEC 62493:2009 samples Average Max [cm] value value Ceiling and/or recessed lighting equipment for fluorescent lamps withan input power 50 65 0,11 0,38 ≤180 W (6) Table lighting equipment (2) 30 7 0,07 0,21 Other lighting equipment not mentioned in 50 25 0.06 0,25 Table A.1 of IEC 62493:2009 (23) Ceiling and/or recessed lighting equipment for fluorescent lamps with an input power 70 3 0,06 0,08 > 180 W (7) Wall lighting equipment (3 ) 50 16 0,05 0,12 Ground recessed lighting equipment (17) 50 1 0,04 0,04 Suspended lighting equipment (5) 50 11 0,04 0,05 Ceilingand/orrecessed lightingequipment for discharge lamps with an input power 70 11 0,04 0.04 ≤180 W (8) Lighting equipment for road and street 200 18 0,03 0,04 lighting (12) Hand lamps (1) 5 1 0,03 0,03 Ceiling and/or recessed lighting equipment for discharge lamps with an input power 100 2 0,03 0,03 >180 W (9) 200 Flood lights (11) 1 0,03 0,03 The number in brackets () represents the position in Table A.1 of IEC 62493:2009. There was no clear result visible in the table. It is therefore not possible to derive further conclusions regardingthe EMFbehaviourfromthis resultand fromtheluminaireclassification inIEC62493:2009,TableA.1. 4.6 Lamp cover The influence of the lamp cover (luminaire construction: housing and different reflector material) is shown in Table 3. Table 3-M

.pdf文档 IEC TR 62493-1 2013 Assessment of lighting equipment related to human exposure to electromagnetic fields - Part 1 Results of the EMF measurement campaign from the VDE Test and Certification Institute

文档预览
中文文档 8 页 50 下载 1000 浏览 0 评论 309 收藏 3.0分
温馨提示:本文档共8页,可预览 3 页,如浏览全部内容或当前文档出现乱码,可开通会员下载原始文档
IEC TR 62493-1 2013 Assessment of lighting equipment related to human exposure to electromagnetic fields - Part 1 Results of the EMF measurement campaign from the VDE Test and Certification Institute  第 1 页 IEC TR 62493-1 2013 Assessment of lighting equipment related to human exposure to electromagnetic fields - Part 1 Results of the EMF measurement campaign from the VDE Test and Certification Institute  第 2 页 IEC TR 62493-1 2013 Assessment of lighting equipment related to human exposure to electromagnetic fields - Part 1 Results of the EMF measurement campaign from the VDE Test and Certification Institute  第 3 页
下载文档到电脑,方便使用
本文档由 人生无常 于 2025-05-10 09:28:00上传分享
友情链接
站内资源均来自网友分享或网络收集整理,若无意中侵犯到您的权利,敬请联系我们微信(点击查看客服),我们将及时删除相关资源。